Omnitron iConverter 100FF User Manual

Browse online or download User Manual for Network media converters Omnitron iConverter 100FF. Omnitron iConverter 100FF

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6
OVERVIEW:
The iConverter fiber-to-fiber chassis plug-in media
converters provide single-mode (SM) to multimode (MM),
dual fiber to single-fiber, wavelength conversion and
fiber extension. Fixed-fiber models are available for
Ethernet, Fast Ethernet, Gigabit Ethernet and
SONET/SDH applications. The Small Form Pluggable
(SFP) model is protocol transparent and also supports
Fibre Channel.
The
iConverter FF media converters can be used in a
managed or unmanaged configuration. Management of
the FF is accomplished by installing a Management
Module
1
(such as an iConverter NMM2 or 10/100M2) in
the same chassis. Management provides monitoring,
configuration and trap notification. When unmanaged, it
can be installed in a chassis without a Management
Module.
1
For complete management support, use a M2 series module (NMM2,
GX/TM2, 2GXM2, 10/100M2, 2FXM2) or higher. The xFF (8699-0)
module must be at rev xx/09 or greater. All revisions of FF modules are
supported.
iConverter
®
100FF, OC3FF, OC12FF, 1000FF and xFF
Fiber-to-Fiber Converter Plug-in Module
User Manual
Port 1 (P1)
Port 2 (P2)
iConverter 1000FF Dual Fiber Modules
Connector
SC/SC
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8642-0
MM 220/550m
1
850 850
MM 220/550m
1
850 850
8642-1
MM 220/550m
1
850 850
SM 12km 1310 1310
8642-2
MM 220/550m
1
850 850
SM 34km 1310 1310
8642-3
MM 220/550m
1
850 850
SM 80km 1550 1550
8643-2
SM 12km 1310 1310
SM 34km 1310 1310
8643-3
SM 12km 1310 1310
SM 80km 1550 1550
ST/SC iConverter 1000FF Single-Fiber Modules
8650-1
MM 220/550m
1
850 850
SM SF 20 km 1310 1550
8651-1
MM 220/550m
1
850 850
SM SF 20 km 1550 1310
8652-1
SM 12 km 1310 1310
SM SF 20 km 1310 1550
8653-1
SM 12 km 1310 1310
SM SF 20 km 1550 1310
8650-2
MM 220/550m
1
850 850
SM SF 40 km 1310 1550
8651-2
MM 220/550m
1
850 850
SM SF 40 km 1550 1310
8652-2
SM 12 km 1310 1310
SM SF 40 km 1310 1550
8653-2
SM 12 km 1310 1310
SM SF 40 km 1550 1310
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
iConverter
100FF Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST SC/SC
8620-1 8622-1
MM 5km 1310 1310
SM 30km 1310 1310
8620-2 8622-2
MM 5km 1310 1310
SM 60km 1310 1310
- 8622-3
MM 5km 1310 1310
SM 120km 1550 1550
ST/SC SC/SC
iConverter
100FF Single-Fiber Modules
8630-1 8634-1
MM 5 km 1310 1310
SM SF 20 km 1310 1550
8631-1 8635-1
MM 5 km 1310 1310
SM SF 20 km 1550 1310
8630-2 8634-2
MM 5 km 1310 1310
SM SF 40 km 1310 1550
8631-2 8635-2
MM 5 km 1310 1310
SM SF 40 km 1550 1310
8632-1 8636-1
SM 30 km 1310 1310
SM SF 20 km 1310 1550
8633-1 8637-1
SM 30 km 1310 1310
SM 20 km 1550 1310
8632-2 8636-2
SM SF 30 km 1310 1310
SM 40 km 1310 1550
8633-2 8637-2
SM 30 km 1310 1310
SM SF 40 km 1550 1310
iConverter OC3FF Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST SC/SC
8660-1 8661-1
MM 5km 1310 1310
SM 30km 1310 1310
8660-2 8661-2
MM 5km 1310 1310
SM 60km 1310 1310
8661-3
MM 5km 1310 1310
SM 120km 1550 1550
ST/SC SC/SC
iConverter OC3FF Single-Fiber Modules
8670-1 8674-1
MM 5 km 1310 1310
SM SF 20 km 1310 1550
8671-1 8675-1
MM 5 km 1310 1310
SM SF 20 km 1550 1310
8670-2 8674-2
MM 5 km 1310 1310
SM SF 40 km 1310 1550
8671-2 8675-2
MM 5 km 1310 1310
SM SF 40 km 1550 1310
8672-1 8676-1
SM 30 km 1310 1310
SM SF 20 km 1310 1550
8673-1 8677-1
SM 30 km 1310 1310
SM SF 20 km 1550 1310
8672-2 8676-2
SM 30 km 1310 1310
SM SF 40 km 1310 1550
8673-2 8677-2
SM 30 km 1310 1310
SM SF 40 km 1550 1310
iConverter
OC12FF Dual Fiber Modules
Connector
SC/SC
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
8681-1
MM 220/550m
1
1310 1310
SM 12km 1310 1310
8681-2
MM 220/550m1 1310 1310
SM 34km 1310 1310
8681-3
MM 220/550m
1
1310 1310
SM 80km 1550 1550
SC/SC
iConverter
OC12FF Single-Fiber Modules
8690-1
MM 220/550m
1
1310 1310
SM SF 20 km 1310 1550
8691-1
MM 220/550m
1
1310 1310
SM SF 20 km 1550 1310
8692-1
SM 12 km 1310 1310
SM SF 20 km 1310 1550
8693-1
SM 12 km 1310 1310
SM SF 20 km 1550 1310
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
iConverter xFF Dual Fiber Modules
Connector
SFP
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8699-0
-
-
- -
- - - -
Refer to the SFP data sheet for supported transceivers.
Page 7 Page 8 Page 9 Page 10 Page 11 Page 12
LINK MODES:
The iConverter fiber-to-fiber media converters support
two different linking modes.
Fig. 1 Link Modes
In Link Propagate (LP) mode (sometimes referred to as
Link Loss Carry Forward), a port transmits a Link signal
only when receiving a Link on the other front-plane port,
and a loss of a received Link at one port causes the
other front-plane port to stop transmitting its link signal.
For example, P1 transmits a Link only when receiving a
Link at P2 [Fig 1(a)].
In Remote Fault Detection (RFD) mode, a port transmits
a Link signal only when both itself and the other port are
receiving Link signals. A loss of a received Link signal
at a port is Looped-back and the port stops transmitting
a Link signal. The same loss of Link is propagated to
the other port which also stops transmitting the Link
signal. For example, the loss of Link into P2 causes
both P1 and P2 ports to stop transmission of the Link
signal [Fig 1(b)].
Note: Connecting two adjacent converters which
are both set to RFD is not permitted and will cause
a “deadly embrace” lockup.
Form: 040-08600-001N 6/10
FRONT PANEL DIP-SWITCH SETTINGS:
Left / Down Right / Up
Fig. 2 Front Panel Dip-Switches
Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no effect. The LS function of this
DIP-Switch has been disabled to enhance compatibility
with third-party fiber optic devices.
iConverter
fiber-to-fiber media converters normally operate in LP
mode.
Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position,
the Remote Fault Detection mode is enabled and LP
mode is disabled. When in the Normal “Norm” position
(factory setting), Remote Fault Detection is disabled
and LP mode is enabled.
LED INDICATORS:
LED Color Description
Pwr: Yellow On--Power on
Lk/Rx (P1): Green On--Link Off--No Link
Lk/Rx (P2): Green On--Link Off--No Link
Warning
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of 2
YEARS from the date of shipment. A LIFETIME limited
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. To register, complete and mail
or fax the enclosed Registration Card to the indicated
address. You may also register your product on the internet
at www.omnitron-systems.com/Register. During the
warranty period, Omnitron will, at its option, repair or replace
a product which is proven to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense. Omnitron
will pay the shipping charge to return the product to Buyer’s
designated US address (within the 48 contiguous states
and the District of Columbia) using Omnitron’s standard
shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including repairs of equipment
by personnel not specifically authorized and certified by
Omnitron, or misuse, or operating outside the environmental
specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or
improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Technical Support:
For help with this product, contact our Technical Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
URL: www.omnitron-systems.com
MOUNTING AND CABLE ATTACHMENT:
iConverter modules are hot-swappable and can be installed
into any chassis in the
iConverter family.
1. Carefully slide the
iConverter module into installation slot,
aligning the module with the installation guides. NOTE:
Ensure that the module is firmly seated against backplane.
2. Secure the module by securing the panel fastener
screw (attached to module) to chassis front.
3. When using an SFP model (8699-0), insert the SFP
Fiber transceivers into the SFP receptacles on the
module.
Note: The release latch of the SFP Fiber transceiver
must be in the closed position before insertion.
The tranceivers installed must have matching
speeds to operate.
4. Attach an appropriate multimode or single-mode fiber
cable to each fiber connector. The transmit cable (Tx)
must attach to the receive side on the other device; the
receive cable (Rx) must attach to the transmit.
5. When using single-fiber (SF) models, the Tx
wavelength on one end must match the Rx wavelength
on the other and the converters must be used in
matched pairs (example: model 8670-1 must be
matched with model 8671-1).
FIBER-TO-FIBER SPECIFICATIONS:
Model Type 100FF 1000FF OC3FF OC12FF xFF
Protocols
100BASE-FX,
100BASE-BX,
100BASE-LX
1000BASE-SX,
1000BASE-LX,
1000BASE-ZX,
1000BASE-BX
OC-3 OC-12
100BASE-FX,
1000BASE-X, OC-3,
OC-12, OC48,
Fibre Channel 1x/2x/4x
Maximum
Data Rate
155Mbps 1.25Gbps 155Mbps 1.25Gbps 4.25Gbps
Fiber
Connectors
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
SFP
Controls
Link Propagate, Remote Fault Detection
LED
Displays
Power,
Fiber Optic Link (2)
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A,
NEBS Level 3
Power
Requirement
(typical)
0.5A @ 3.3VDC
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95%
(non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
1,300,000
Page view 0
1

Summary of Contents

Page 1 - iConverter

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6OVERVIEW:The iConverter fiber-to-fiber chassis plug-in mediaconverters provide single-mode (SM) to multimode

Comments to this Manuals

No comments