Omnitron miConverter Gx User Manual

Browse online or download User Manual for Network media converters Omnitron miConverter Gx. Omnitron miConverter Gx

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 2 Page 3
Page 6
Page 4
Page 5
Page 7 Page 8
the miConverter Gx transmitter (Tx) must attach to the
receiver side of its link partner; the receiver (Rx) must
attach to the transmitter. When connecting single-fiber
(SF) models, the Tx wavelength on one end has to match
the Rx wavelength on the other. Based on this guideline,
the SF media converter models must be used in pairs,
such as the 1210-2-x matched with the 1211-2-x.
4. Mount the miConverter Gx using the included Velcro
®
strips or optional wall-mounting bracket kit (P/N 1091-0).
5. Connect the appropriate power supply.
DIP-SWITCH SETTINGS:
Fig. 1 DIP-switches
Fiber Optic Auto/Manual “AN/Man” DIP-switch:
Setting this DIP-switch to the Auto-negotiation “AN”
(factory default) setting enables the fiber optic port of the
miConverter Gx to negotiate the Duplex and Pause modes
with the connected fiber optic and UTP devices. The
DESCRIPTION:
The miConverter
Gx converts between 1000BASE-T
copper and 1000BASE-X Gigabit Ethernet fiber. The
fiber optic port supports Auto-negotiation and Manual
configuration via DIP-switches. The UTP port
automatically detects and advertises the Duplex and
Pause abilities of connected Gigabit fiber optic and
UTP devices.
The 1000BASE-X fiber port supports ST and SC fiber
connectors. Single-fiber and dual fiber models are
listed in the table on the first page of this manual.
WARNING!
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.
POWER ADAPTER NOTICE:
This product should only be used with Omnitron supplied
Power Supply model numbers 9113-PS, 9115-PS, 9116-PS-3,
9116-PS-4, 9116-PS-5 or 9116-PS-8.
When powering the
miConverter Gx using the USB Power
Adapter cable (P/N 9130-2), the cable must be connected
to a Full-Powered USB Type-A port (5V, 500mA).
Note: Not all USB Type-A ports are Full-Powered USB
ports. The Full-Powered USB Type-A ports are usually
the USB ports found on computer cases or on
self-powered (powered by an AC adapter) USB hubs.
INSTALLATION PROCEDURE:
1. Configure the appropriate miConverter Gx DIP-switch
settings. If connecting to a fiber optic device that is set
to auto-negotiation mode, set the fiber optic
Auto-negotiation/Manual “AN/Man” DIP-switch to “AN.”
If connecting to a fiber optic device that is set to manual
mode, set the fiber optic “AN/Man” switch to “Man” and
the UTP DIP-switches to the settings of the connected
devices.
2. Connect the UTP port to a 1000BASE-T Ethernet device
using a Category 5 cable (or better).
3. Connect the fiber optic port to a 1000BASE-X Gigabit
Ethernet device using a single-mode or multimode fiber
cable (as appropriate). When connecting dual fiber models,
miConverter
Gx Media Converter
User Manual
miConverter Gx UTP port negotiates with the connected
UTP device based on the modes detected by the fiber
optic port. Both the
miConverter Gx and the connected
fiber optic device must have their fiber optic
auto-negotiation enabled for this process to work.
Setting this DIP-switch to the Manual “Man” setting
disables the fiber optic port’s ability to detect the Duplex
and Pause modes of the connected fiber optic device.
In this setting, the UTP port of the miConverter Gx
negotiates with the connected UTP device based on the
modes configured by the UTP DIP-switches. This
setting allows the
miConverter Gx to connect to Gigabit
fiber devices that are not capable of auto-negotiation.
Note: In auto-negotiation mode, connecting the
fiber optic cables before connecting the UTP cables
causes the fiber optic LED to blink steadily (0.5Hz).
The blinking LED turns solid when the UTP link is
on and blinks quickly (10Hz) when activity is
detected.
Note: The UTP “FDX/HDX”, “Pause/No”, and
“LS/LP” DIP-switches have no affect when the fiber
optic port is set to auto-negotiation.
UTP Full/Half Duplex “FDX/HDX” DIP-switch:
Setting this DIP-switch to “FDX” (factory default) allows
the UTP port to negotiate to Full-Duplex. Setting this
DIP-Switch to “HDX” forces the UTP port to negotiate
only to Half-Duplex. These settings must be
configured to match the settings of the connected fiber
optic and UTP devices.
LED INDICATORS:
Note: For additional assistance with LED
indicators, please refer to the miConverter Gx
TROUBLESHOOTING GUIDE (pp. 11-12).
Optional Accessories
Wall-Mounting Hardware Kit 1091-0
USB Power Adapter Cable 9130-2
US Domestic AC Power Supply 9113-PS
Universal AC Power Supply
(requires AC power cord)
9115-PS
Europe AC Power Supply 9116-PS-3
UK AC Power Supply 9116-PS-4
Australia AC Power Supply 9116-PS-5
Japanese AC Power Supply 9116-PS-8
Europe Connector Clip* 9116-3
UK Connector Clip* 9116-4
Australia Connector Clip* 9116-5
Japanese Connector Clip* 9116-8
*All spare Connector Clips are interchangeable with AC
Power Adapters 9116-PS-3, 9116-PS-4, 9116-PS-5 and 9116-PS-8
*Unit shown with optional wall-mounting bracket kit
Function Color Legend Off State On / Blinking State
Power Amber PWR No power Amber = power
F/O link Act Green F/O No fiber
optic link
Green = link
Green rapid blink (10Hz) = data
Green slow blink (0.5Hz) = fibe
r
cable is connected but unable
to complete auto-negotiation
F/O Auto-Neg Green AN Manual
mode
Auto-negotiation mode
UTP-link Act Green UTP No UTP
link
Green = link
Green rapid blink (10Hz) = data
Full-Half
Duplex
Green FDX UTP is at
Half-Duplex
UTP is at Full-Duplex
UTP Pause Enable/Disable “Pause/No” DIP-switch:
Setting this DIP-switch to “Pause” (factory default) allows
the UTP port to negotiate to Symmetrical Pause. Setting
this DIP-switch to “No” disables Pause. These settings
must be configured to match the settings of the
connected fiber optic and UTP devices.
Link Segment/Link Propagate “LS/LP” DIP-switch:
Setting this DIP-switch to “LS” (factory default) allows the
generation and detection of link presence to occur at each
point-to-point segment. In this configuration, the loss of a
receive link on either port has no affect on the other port’s
ability to transmit a link. For example, if there is a loss of
a receive link on the fiber optic port, the UTP port continues
to maintain its link [Fig.2 (A) & (B)].
Setting this DIP-switch to “LP” allows the link state to
propagate from one port to the other port. In this
configuration, the loss of a receive link on either port causes
the transmit link of the opposite port to be turned off.
For example, a loss of a receive link on the fiber optic
port causes the UTP port to drop its link due to the
propagated fiber optic link state [Fig. 2 (C)]. This
setting allows the loss of a link to be detected by
SNMP or other managed network devices to which the
miConverter Gx is connected.
Note: Only the first loss of a receive link detected by
the miConverter Gx turns off the other port’s transmit
link. An additional loss of a receive link on the other
port has no affect on the miConverter Gx. The
miConverter Gx returns to normal operation when the
first loss of a receive link is restored.
(A)
(
B)
(
C)
Fig. 2 Manual Link Modes
Link Propagate “LP”
UTP No Pause “No”
F/O Auto-negotiate “AN”
UTP Half-Duplex “HDX”
UTP Pause Enabled “Pause”
F/O Manual Negotiate “Man”
UTP Full-Duplex “FDX”
Link Segment “LS”
UP
DOWN
miConverter GX Models
Fiber Type
Dual Fiber [DF] or
Single-Fiber [SF]
Distance
ST
Connector
SC
Connector
Tx
Wavelength
[nm]
Rx
Wavelengt
h
[nm]
MM / DF 220m 1200-0-x 1202-0-x 850 850
SM / DF 12km - 1203-1-x 1310 1310
SM / DF 34km - 1203-2-x 1310 1310
SM / DF 80km - 1203-3-x 1550 1550
SM / SF 20km - 1210-1-x 1310 1550
SM / SF 20km - 1211-1-x 1550 1310
SM / SF 40km - 1210-2-x 1310 1550
SM / SF 40km - 1211-2-x 1550 1310
When ordering power options, replace (-x) in the model number with
the suffix number that corresponds to the selected power supply.
Example: 1203-2-6 = SM/DF/34km with a USB Power Adapter Cable.
-1 US Power Supply - 120Volt / 60Hz
-2 Universal Power Supply (requires AC power cord) - 100-240Volt / 50-60Hz
-3 Europe Power Supply - 100-240Volt / 50-60Hz
-4 UK Power Supply - 100-240Volt / 50-60Hz
-5 Australia Power Supply - 100-240Volt / 50-60Hz
-6 USB Power Adapter Cable
-8 US/JPN Power Supply - 100-240Volt / 50-60Hz
For power supplies -3, -4, -5 and -8, country/region specific clips are used to provide the
necessary power connection.
Page view 0
1 2

Summary of Contents

Page 1

Page 2 Page 3Page 6Page 4Page 5Page 7 Page 8the miConverter Gx transmitter (Tx) must attach to thereceiver side of its link partner; the receiver (Rx)

Page 2 - TROUBLESHOOTING GUIDE:

Page 15Page 10 Page 11Page 12Page 9Page 14Page 16SPECIFICATIONS:Form: 040-12000-001D 11/07WarningThe operating description in this Instruction Manua